Table 3-1 (Page 21 of 40). Firmware Error Codes.
Error Code
Description
2BA00326
Service Processor reports PCI
Expansion Card 5V Over Voltage
Alert
2BA00327
Service Processor reports PCI
Expansion Card 5V Under Voltage
Alert
2BA00328
Service Processor reports PCI
Expansion Card 3.3V Over Voltage
Alert
2BA00329
Service Processor reports PCI
Expansion Card 3.3V Under Voltage
Alert
2BA00330
Service Processor reports PCI
Expansion Card +12V Over Voltage
Alert
2BA00331
Service Processor reports PCI
Expansion Card +12V Under
Voltage Alert
2BA00332
Service Processor reports PCI
Expansion Card -12V Over Voltage
Alert
2BA00333
Service Processor reports PCI
Expansion Card -12V Under Voltage
Alert
2BA00334
Service Processor reports Generic
Slow Shutdown request
2BA00335
Service Processor reports CPU Crit-
ical Over Temperature Slow Shut-
down request
2BA00336
Service Processor reports IO Critical
Over Temperature Slow Shutdown
request
3-22
RS/6000 Enterprise Server Model H Series Installation and Service Guide
Action / Possible Failing FRU
1. Replace power supply.
2. Replace I/O Board (See notes on 3-1.)
1. Replace power supply.
2. Replace I/O Board (See notes on 3-1.)
1. Replace power supply.
2. Replace I/O Board (See notes on 3-1.)
1. Replace power supply.
2. Replace I/O Board (See notes on 3-1.)
1. Replace power supply.
2. Replace I/O Board (See notes on 3-1.)
1. Replace power supply.
2. Replace I/O Board (See notes on 3-1.)
1. Replace power supply.
2. Replace I/O Board (See notes on 3-1.)
1. Replace power supply.
2. Replace I/O Board (See notes on 3-1.)
1. Replace power supply.
2. Replace I/O Board (See notes on 3-1.)
1. Check for cool air flow obstructions to
the system.
2. Check fans for obstructions that
prevent them from normal operation
(example: a cable caught in the fan
preventing it from spinning).
3. If problem persists, replace CPU Card.
1. Check for cool air flow obstructions to
the system.
2. Check fans for obstructions that
prevent them from normal operation
(example: a cable caught in the fan
preventing it from spinning).
3. If problem persists, replace I/O Board
(See notes on 3-1.)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs/6000 h seriesRs/6000 h50Rs/6000 h70

Table of Contents