Table 3-1 (Page 25 of 40). Firmware Error Codes.
Error Code
Description
40110003
Voltage is present, but not detected
on one processor card. (If the
system is running, refer to the AIX
error log to find out which processor
card is failing. If the system is not
running, refer to the service
processor error log.)
40110004
For Model H50: Loss of redundant
power supply. (If the system is
running, refer to the AIX error log to
find out which processor card is
failing. If the system is not running,
refer to the service processor error
log.) For Model H70: Low voltage
D
detected in power supply main
D
enclosure.
D
40110005
For Model H50: Loss of redundant
power supply and a DASD fan.
(Refer to the service processor error
log to determine which fan and
power supply is failing.) For Model
H70: Fan warning detected in power
D
supply main enclosure.
D
D
D
40110006
Fan failure detected in power supply
D
main enclosure
D
D
40110007
Thermal warning detected in power
D
supply main enclosure
D
D
40110008
Thermal failure detected in power
D
supply main enclosure
D
D
40110009
High 5.0 volt detected in power
D
supply main enclosure
D
D
D
D
40110015
Service processor detects less than
D
D
200V minimum required to run the
D
D
system.
D
4011000A
High 5.0 RA volt detected in power
D
supply main enclosure
D
3-26
RS/6000 Enterprise Server Model H Series Installation and Service Guide
Action / Possible Failing FRU
For Model H50:
1. Check cable between CPU card and
PDB for proper seating.
2. Replace CPU card.
3. Replace cable between CPU card and
PDB.
4. Replace PDB.
For Model H70: Replace power supply.
For Model H50:
1. Power supply.
2. PDB.
3. I/O board. (See notes on 3-1.)
For Model H70:
1. Check fan monitor cable to connector
on I/O Board.
2. Power supply.
For Model H50:
1. Power supply.
2. DASD fan.
For Model H70:
1. Check fan monitor cable to connector
on I/O Board.
2. Power supply.
1. Check fan monitor cable to connector
on I/O Board.
2. Power supply.
1. Check fan monitor cable to connector
on I/O Board.
2. Power supply.
1. Check fan monitor cable to connector
on I/O Board.
2. Power supply.
1. Check fan monitor cable to connector
on I/O Board.
2. Power supply.
1. Check power coming into the system
to ensure it is 200-240V.
2. Power supply.
1. Check fan monitor cable to connector
on I/O Board.
2. Power supply.