Table 3-1 (Page 18 of 40). Firmware Error Codes.
Error Code
Description
2BA00071
VPD data corrupted for CPU in
processor card connector #1
2BA00073
VPD data corrupted for CPU in
processor card connector #2
2BA00080
VPD module missing from memory
card(s)
2BA00081
VPD data corrupted on first memory
card
2BA00083
VPD data corrupted on second
memory card
2BA00100
Service processor firmware recovery
information could not be written to
diskette
2BA00101
Service processor is not installed,
update cancelled
2BA00102
No service processor update
diskette in drive
2BA00103
Service processor firmware update
file is corrupted, update cancelled
2BA00104
Service processor firmware update
file is the same level as the service
processor firmware, update can-
celled
Action / Possible Failing FRU
Replace the CPU card in processor card
connector #1.
Replace the CPU card in processor card
connector #2.
1. Remove the memory card at location
P1-M2, if installed, and see if the
problem is resolved. If the problem is
resolved, replace the memory card
that was just removed. If not, go to
step 2.
2. Exchange the memory card at P1-M1
with the memory card remove in step
1 (or replace the memory card at
P1-M1 if only one memory card is
installed) and see if the problem is
resolved. If the problem is resolved,
replace the card at P1-M1.
Replace the first memory card. location:
P1-M1
Replace the second memory card,
location: P1-M2
1. Check diskette media write protect
tab.
2. Replace the diskette drive.
1. Install the service processor (Model
H50 only).
2. Retry operation.
Insert the diskette.
1. Obtain new service processor
firmware diskette.
2. Retry operation.
1. Obtain new level of service processor
firmware.
2. Retry operation.
Chapter 3. Error Code to FRU Index
3-19