Step 1540-7
The memory module(s) (may be both) you exchanged in the previous step may be
defective. To isolate the failing memory module, do the following:
1. Turn the power off and remove the power cable.
2. Reinstall one of the memory modules you exchanged in the previous step.
3. Plug in the power cable and wait for OK on the operator panel display.
4. Turn the power on.
Does the system stop with code E1F2, E1F3, STBY, 20EE000B or 4BA00830
displayed on the operator panel?
NO
Replace the memory module.
If you have not tested both memory modules repeat this step with the
second memory module you exchanged in the previous step.
If the symptom did not change and both memory modules have been
exchanged go to "Step 1540-8" on page 2-45.
YES
Repeat this step with the second memory module you exchanged in the
previous step.
If both memory modules have been tested go to "Map 0410: Repair
Checkout" in the Diagnostic Information for Multiple Bus Systems.