IBM H Series Installation And Service Manual page 213

Enterprise server
Table of Contents

Advertisement

Loops and Data Paths
All devices that are attached to an SSA adapter card are connected through SSA
links. The SSA links are configured as loops. Data and commands to a particular
device pass through all other devices on the link between the adapter and the target
device.
Data can travel in either direction around a loop. The adapter can, therefore, access
the disk drive modules through two data paths. The using system cannot detect
which data path is being used.
If a disk drive module fails or is turned off, the loop is broken and one of the data
paths to a particular module is no longer available. The disk drive modules on the
loop continue to work, but an error is reported to the using system.
The following diagram shows that the disk drive module in slot 3 has failed. The disk
drive modules in slots 1 and 2 can communicate with the using system only through
connector A1 of the SSA adapter. The disk drive modules in slots 4, 5, and 6 can
communicate only through connector A2 of the SSA adapter.
5-17
Chapter 5. SSA Software and Microcode Errors

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs/6000 h seriesRs/6000 h50Rs/6000 h70

Table of Contents