Changing acceleration and deceleration time
(Pr. 7, Pr. 8)

4.4 Changing acceleration and deceleration time (Pr. 7, Pr. 8)

Set in Pr. 7 Acceleration time a larger value for a slower speed increase and a smaller value for a faster speed increase.
Set in Pr. 8 Deceleration time a larger value for a slower speed decrease and a smaller value for a faster speed decrease.
Parameter
Name
Number
7
Acceleration time
8
Deceleration time
* Depends on the Pr. 21 Acceleration/deceleration time increments setting. The initial value for the setting range is "0 to 3600s" and setting increments is
"0.1s".
Changing example
Change the Pr. 7 Acceleration time setting from "5s"
to "10s".
1.
Screen at powering on
The monitor display appears.
2.
Press
mode.
3.
Press
setting mode.
4.
5.
Press
"
"(initial value) appears.
6.
Turn
to change it to the set
value "
7.
Press
68
Initial Value
7.5K or less
11K or more
7.5K or less
11K or more
Operation
to choose the PU operation
to choose the parameter
Pr. 7) appears.
to read the present set value.
".
to set.
· By turning
, you can read another parameter.
· Press
to show the setting again.
· Press
twice to show the next parameter.
Setting
Range
5s
0 to 3600/
360s
15s
*
10s
0 to 3600/
360s
30s
*
Pr.20
(60Hz)
Acceleration
time
Display
PU indication is lit.
The parameter
number read
Flicker ··· Parameter setting complete!!
Description
Set the motor acceleration time.
Set the motor deceleration time.
Running
frequency
Time
Deceleration
Pr.7
Pr.8
time
previously appears.
The initial value
differs according
to the capacity.