Parameter list
Parameter
RUN terminal
190
function selection
SU terminal
191
function selection
IPF terminal
192
function selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal
195
function selection
ABC2 terminal
196
function selection
232 to 239
Refer to Pr.4 to Pr.6.
240
Refer to Pr.72.
241
Refer to Pr.125 and Pr.126.
242, 243
Refer to Pr.73.
94
Incre
Initial
Name
ments
Value
1
0
1
1
1
2
1
3
1
4
1
99
1
9999
Range
Description
0, 100: Inverter running (RUN)
1, 101: Up to frequency (SU)
2, 102: Instantaneous power failure/
undervoltage (IPF)
3, 103: Overload warning (OL)
4, 104: Output frequency detection (FU)
5, 105: Second output frequency detection
(FU2)
7, 107: Regenerative brake prealarm
(RBP) (Only for the 75K or more)
8, 108: Electronic thermal relay function
0 to 5, 7, 8,
prealarm (THP)
10 to 19, 25,
10, 110: PU operation mode (PU)
26, 45 to 48,
11, 111: Inverter operation ready (RY)
64, 70, 79,
12, 112: Output current detection (Y12)
85, 90 to 96,
13, 113: Zero current detection (Y13)
98, 99,
14, 114: PID lower limit (FDN)
100 to 105,
15, 115: PID upper limit (FUP)
107, 108,
16, 116: PID forward/reverse rotation
110 to 116,
output (RL)
125, 126,
17, —: Bypass operation switchover MC1
145 to 148,
(MC1)
164, 170,
18, —: Bypass operation switchover MC2
179, 185,
(MC2)
190 to 196,
19, —: Bypass operation switchover MC3
198, 199,
(MC3)
9999
25, 125: Fan fault output (FAN)
26, 126: Heatsink overheat pre-alarm (FIN)
45, 145: Inverter running and start
command is on (RUN3)
46, 146: During deceleration at occurrence
of power failure (retained until
release) (Y46)
47, 147: During PID control activated (PID)
48, 148: PID deviation limit (Y48)
64, 164: During retry (Y64)
70, 170: PID output interruption (SLEEP)
79, 179: Pulse train output of output power
0 to 5, 7, 8,
(Y79)
10 to 19, 25,
85, 185: DC current feeding (Y85)
26, 45 to 48,
90, 190: Life alarm (Y90)
64, 70, 79,
91, 191: Fault output 3 (power-off signal)
85, 90, 91,
(Y91)
94 to 96, 98,
92, 192: Energy saving average value
99,
updated timing (Y92)
100 to 105,
93, 193: Current average monitor signal
107, 108,
(Y93)
110 to 116,
94, 194: Fault output 2 (ALM2)
125, 126,
95, 195: Maintenance timer signal (Y95)
145 to 148,
96, 196: Remote output (REM)
164, 170,
98, 198: Alarm output (LF)
179, 185,
99, 199: Fault output (ALM)
190, 191,
9999: No function
194 to 196,
0 to 99: Positive logic, 100 to 199: Negative
198, 199,
logic
9999
All
Para
Para
para
meter
meter
meter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×