4.6 Selection of the operation command and frequency
command locations (Pr. 79)
Select the start command location and frequency command location.
Parameter
Initial
Name
Number
Value
Operation
79
mode
selection
*1
The priorities of the frequency commands when Pr. 79 = "3" are "Multi-speed operation (RL/RM/RH/REX) > PID control (X14) > terminal 4 analog
input (AU) > digital input from the operation panel".
*2
For the terminal used for the X12 signal (PU operation interlock signal) input, set "12" in Pr. 178 to Pr. 189 (input terminal function selection) to assign
functions.
For Pr. 178 to Pr. 189, refer to the chapter 4 of
When the X12 signal is not assigned, function of the MRS signal switches from MRS (output stop) to PU operation interlock signal.
Setting
Range
Use external/PU switchover mode (press
between the PU and External operation mode. (Refer to
0
page 48))
At power on, the inverter is in the External operation
mode.
1
Fixed to PU operation mode
Fixed to External operation mode
2
Operation can be performed by switching between the
external and NET operation mode.
External/PU combined operation mode 1
Running frequency
PU (FR-DU07/FR-PU04/
FR-PU07) setting or
3
external signal input (multi-
speed setting, across
terminals 4-5 (valid when
AU signal turns on)).
0
External/PU combined operation mode 2
Running frequency
4
External signal input
(Terminal 2, 4, 1, JOG,
multi-speed selection, etc.)
Switchover mode
6
Switch among PU operation, external operating, and
NET operation while keeping the same operating status.
External operation mode (PU operation interlock)
X12 signal ON
Operation mode can be switched to the PU operation
mode.
7
(output stop during external operation)
X12 signal OFF
Operation mode can not be switched to the PU
operation mode.
the Instruction Manual (applied).
Selection of the operation command and
frequency command locations (Pr. 79)
Description
Start signal
External signal input
(terminal STF, STR)
*1
Start signal
Input from the PU (FR-
DU07/FR-PU04/FR-PU07)
(
,
)
*2
*2
LED Indication
: Off
: On
External operation mode
to switch
PU operation mode
External operation mode
NET operation mode
PU operation mode
External operation mode
NET operation mode
PU operation mode
External operation mode
4
71