Mitsubishi Electric F700 Instruction Manual page 106

Hide thumbs Also See for F700:
Table of Contents

Advertisement

Parameter
Name
Regeneration
882
avoidance
operation selection
Regeneration
883
avoidance
operation level
Regeneration
avoidance at
884
deceleration
detection sensitivity
Regeneration
avoidance
885
compensation
frequency limit
value
Regeneration
886
avoidance voltage
gain
888
Free parameter 1
889
Free parameter 2
Incre
Initial
Range
ments
Value
0
Regeneration avoidance function invalid
Regeneration avoidance function is always
1
1
0
valid
Regeneration avoidance function is valid
2
only during a constant speed operation
Set the bus voltage level at which
regeneration avoidance operates. When
the bus voltage level is set to low,
DC380V
overvoltage error will be less apt to
0.1V
300 to 800V
occur. However, the actual deceleration
/760V*
time increases.
* The initial value differs according to the
voltage level. (200V class / 400V class)
Set sensitivity to detect the bus voltage
1
0
0 to 5
change.
1 (Low) → 5 (High)
Set the limit value of frequency which rises
0 to 10Hz
at activation of regeneration avoidance
function.
0.01Hz
6Hz
9999
Frequency limit invalid
Adjust responsiveness at activation of
regeneration avoidance.
A larger setting will improve
0.1%
100%
0 to 200%
responsiveness to the bus voltage change.
However, the output frequency could
become unstable.
Parameters you can use for your own
1
9999
0 to 9999
purposes.
Used for maintenance, management, etc.
by setting a unique number to each inverter
1
9999
0 to 9999
when multiple inverters are used.
Parameter list
Para
meter
copy
Description
All
Para
para
meter
meter
clear
clear
: enabled
× : disabled
×
×
×
×
4
99

Hide quick links: