Setting Of Acceleration/Deceleration Time And Acceleration/ Deceleration Pattern; Setting Of The Acceleration And Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147) - Mitsubishi Electric FR-E720-600 Instruction Manual

Hide thumbs Also See for FR-E720-600:
Table of Contents

Advertisement

Setting of acceleration/deceleration time and acceleration/ deceleration pattern

4.8
Setting of acceleration/deceleration time and acceleration/
deceleration pattern
Purpose
Motor acceleration/deceleration
time setting
Starting frequency
Set acceleration/deceleration
pattern suitable for application
Automatically set optimum
acceleration/deceleration time.
4.8.1
Setting of the acceleration and deceleration time
(Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)
Used to set motor acceleration/deceleration time.
Set a larger value for a slower speed increase/decrease or a smaller value for a faster speed increase/decrease.
For the acceleration time at automatic restart after instantaneous power failure, refer to Pr. 611 Acceleration time at a
restart (page 154).
Parameter
Name
Number
7
Acceleration time
8
Deceleration time
Acceleration/
20 ∗1
deceleration
reference frequency
Acceleration/
21 ∗1
deceleration time
increments
Second acceleration/
44 ∗1
deceleration time
Second deceleration
45 ∗1
time
Acceleration/
147∗1
deceleration time
switching frequency
∗1
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 180)
∗2
Depends on the Pr. 21 Acceleration/deceleration time increments setting. The initial value for the setting range is "0 to 3600s" and the setting increments is "0.1s".
102
Parameter that should be Set
Acceleration/deceleration
times
Starting frequency and
start-time hold
Acceleration/deceleration
pattern
Automatic acceleration/
deceleration
Initial Value
FR-E720-175 or less
5s
FR-E740-095 or less
FR-E720-240 and 330
10s
FR-E740-120 and 170
FR-E720-470 and 600
15s
FR-E720-175 or less
5s
FR-E740-095 or less
FR-E720-240 and 330
10s
FR-E740-120 and 170
FR-E720-470 and 600
15s
60Hz
0
FR-E720-175 or less
5s
FR-E740-095 or less
FR-E720-240 and 330
10s
FR-E740-120 and 170
FR-E720-470 and 600
15s
9999
9999
Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44,
Pr. 45, Pr. 147
Pr. 13, Pr. 571
Pr. 29
Pr. 61 to Pr. 63, Pr. 292
Setting
Range
0 to 3600/
Motor acceleration time.
360s ∗2
0 to 3600/
Motor deceleration time.
360s ∗2
Frequency that will be the basis of
1 to 400Hz
acceleration/deceleration time. Pr. 20
Increments: 0.1s
0
Range: 0 to 3600s
Increments: 0.01s
1
Range: 0 to 360s
0 to 3600/
Acceleration/deceleration time when the RT
360s ∗2
signal is on.
0 to 3600/
Deceleration time when the RT signal is on.
360s ∗2
9999
Acceleration time = deceleration time
Frequency when automatically switching to
0 to 400Hz
the acceleration/deceleration time of Pr. 44
and Pr. 45.
9999
No function
Refer to Page
102
105
106
107
Description
Increments and setting
range of acceleration/
deceleration time
setting can be changed.