Mitsubishi Electric F700 Instruction Manual page 144

Hide thumbs Also See for F700:
Table of Contents

Advertisement

Operation
Operating
panel (FR-
status
DU07)
Parameter
unit (FR-
Fault definition
PU07)
Interactive
guidance
Protective
function
Protective/
warning function
Warning
function
Surrounding air temperature
Ambient humidity
Storage temperature
*3
Atmosphere
Altitude, vibration
*1
Can be displayed only on the operation panel (FR-DU07).
*2
This operation guide is only available with option parameter unit (FR-PU07).
*3
Temperature applicable for a short period in transit, etc.
*4
Only the 75K or more functions.
2
*5
2.9m/s
or less for the 185K or more.
*6
This protective function does not function in the initial status.
The following operating status can be displayed: output frequency, motor current (steady or
peak value), output voltage, alarm indication, frequency setting, running speed, converter
output voltage (steady or peak value), electronic thermal relay function load factor, input power,
output power, load meter, cumulative energization time, actual operation time, motor load
factor, cumulative power, power saving effect, cumulative saving power, regenerative brake
duty
,PID set point, PID measured value, PID deviation value, inverter I/O terminal monitor,
*4
input terminal option monitor
, output terminal option monitor
*1
terminal assignment status
*2
Fault definition is displayed when a fault occurs. Past 8 fault definitions (output voltage/current/
frequency/cumulative energization time right before the fault occurs) are stored.
Function (help) for operation guide
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during
deceleration, overvoltage during acceleration, overvoltage during constant speed, overvoltage
during deceleration, inverter protection thermal operation, motor protection thermal operation,
heatsink overheat, instantaneous power failure occurrence, undervoltage, input phase loss
motor overload, output side earth (ground) fault overcurrent, output phase loss, external thermal
relay operation
, PTC thermistor operation
*6
retry count excess
, CPU fault, operation panel power supply short circuit, 24VDC power output
*6
short circuit, output current detection value excess
communication fault (inverter), analog input fault, PID signal fault
power supply), brake transistor alarm detection
Fan alarm, overcurrent stall prevention, overvoltage stall prevention, regenerative brake
prealarm
, electronic thermal relay function prealarm, PU stop, maintenance timer alarm
*6
parameter write error, copy operation error, operation panel lock, parameter copy
-10°C to +50°C (non-freezing)
90%RH or less (non-condensing)
-20°C to +65°C
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Maximum 1000m above sea level for standard operation. After that derate by 3% for every
extra 500m up to 2500m (92%) 5.9m/s
Common specifications
, option fitting status monitor
*1
*2
, option fault, parameter error, PU disconnection,
*6
, inrush current limit circuit fault,
*6
, internal circuit fault (15V
*6
,
*4
2
or less at 10 to 55Hz (directions of X, Y, Z axes)
,
*2
,
*6
,
*1*6
*5
7 7
137