ZyXEL Communications Ethernet Switch Cli Reference Manual page 324

Table of Contents

Advertisement

Chapter 85 Additional Commands
This example looks at the current sensor readings from various places in the hardware.
sysname# show hardware-monitor C
Temperature Unit : (C)
Temperature(%c)
---------------
FAN Speed(RPM)
--------------
Voltage(V)
----------
1.25VIN
1.8VIN
3.3VIN
2.5VIN
The following table describes the labels in this screen.
Table 185 show hardware-monitor
LABEL
Temperature Unit
Temperature
Current
Max
Min
Threshold
Status
FAN Speed(RPM)
Current
Max
Min
Threshold
Status
Voltage(V)
324
Current
Max
-------
-----
CPU
33.0
35.0
MAC
31.0
33.0
LOCAL
33.0
34.0
Current
Max
-------
----
FAN1
7356
7769
FAN2
6087
6279
FAN3
6157
6301
Current
Max
-------
-----
-----
1.243
1.256
1.243
1.869
1.880
1.869
3.372
3.398
3.372
2.593
2.593
2.593
DESCRIPTION
This field displays the unit of measure for temperatures in this screen.
This field displays the location of the temperature sensors.
This field displays the current temperature at this sensor.
This field displays the maximum temperature measured at this sensor.
This field displays the minimum temperature measured at this sensor.
This field displays the upper temperature limit at this sensor.
Normal: The current temperature is below the threshold.
Error: The current temperature is above the threshold.
This field displays the fans in the Switch. Each fan has a sensor that is
capable of detecting and reporting when the fan speed falls below the
threshold.
This field displays the current speed of the fan at this sensor.
This field displays the maximum speed of the fan measured at this sensor.
This field displays the minimum speed of the fan measured at this sensor. It
displays "<41" for speeds too small to measure. (See the User's Guide to
find out what speeds are too small to measure in your Switch.)
This field displays the minimum speed at which the fan should work.
Normal: This fan is running above the minimum speed.
Error: This fan is running below the minimum speed.
This field displays the various power supplies in the Switch. Each power
supply has a sensor that is capable of detecting and reporting when the
voltage is outside tolerance.
Min
Threshold
-----
---------
28.0
85.0
27.0
75.0
28.0
75.0
Min
Threshold
Status
----
---------
------
6569
3000
Normal
6020
3000
Normal
6067
3000
Normal
Min
Threshold
Status
---------
------
+/-6%
Normal
+/-6%
Normal
+/-6%
Normal
+/-6%
Normal
Ethernet Switch CLI Reference Guide
Status
------
Normal
Normal
Normal

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs3700 series

Table of Contents