ZyXEL Communications Ethernet Switch Cli Reference Manual page 320

Table of Contents

Advertisement

Chapter 85 Additional Commands
Table 180 Command Summary: Additional Enable Mode (continued)
COMMAND
<1|2>
boot image
cable-diagnostics <port-list>
ping <ip|host-name> [vlan <vlan-
id>] [size <0-1472>] [-t]
ping help
reload config [1|2]
reset slot <slot-list>
show al1arm-status
show cpu-utilization
show hardware-monitor <C|F>
show memory
show power-source-status
show sfp <port-list>
show interfaces transceiver
<port-list>
show slot
show slot config
show slot config <slot-list>
show system-information
show version [flash]
test interface port-channel
<port-list>
320
DESCRIPTION
The Switch supports dual firmware images, ras-0 and ras-1.
Run this command, where <index> is 1 (ras-0) or 2 (ras-1) to
specify which image is updated when firmware is loaded
using the web configurator and to specify which image is
loaded when the Switch starts up.
Perform a physical wire-pair test of the Ethernet connections
on the specified port(s).
Ok: The physical connection between the wire-pair is okay.
Open: There is no physical connection between the wire-pair.
Sends Ping packets to the specified Ethernet device.
vlan-id: Specifies the VLAN ID to which the Ethernet
device belongs.
size <0-1472>: Specifies the size of the Ping packet.
-t: Sends Ping packets to the Ethernet device indefinitely.
Press [CTRL]+C to terminate the Ping process.
Provides more information about the specified command.
Restarts the system (warm reboot) with the specified
configuration file.
1: config-1
2: config-2
Restarts the card in the selected slot. The card restarts using
the last-saved configuration. Any unsaved changes are lost.
Displays alarm status.
Displays the CPU utilization statistics on the Switch.
This command is not available in all models.
Displays current hardware monitor information with the
specified temperature unit (Celsius C or Fahrenheit F).
Displays the memory utilization statistics on the Switch.
Displays the status of each power module in the system.
Displays real-time SFP (Small Form Facter Pluggable)
transceiver operating parameters on specified SFP port(s).
The parameters include, for example, module temperature,
module voltage, transmitting and receiving power.
Displays real-time SFP (Small Form Facter Pluggable)
transceiver information and operating parameters on
specified SFP port(s). The parameters include, for example,
module temperature, module voltage, transmitting and
receiving power.
Displays general status information about each slot.
Displays what type of card is installed in each slot and its
current operational status.
Displays detailed information about the specified slots.
Displays general system information.
Display the version of the currently running firmware on the
Switch. Optionally, display the version of the currently
installed firmware on the flash memory.
Performs an internal loopback test on the specified ports. The
test returns Passed! or Failed!.
Ethernet Switch CLI Reference Guide
M
P
E
13
E
13
E
0
E
0
E
13
E
13
E
0
E
0
E
0
E
3
E
0
E
3
E
3
E
13
E
13
E
13
E
0
E
0
E
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs3700 series

Table of Contents