(5) Options and auxiliary equipment
Use UL/C-UL standard-compliant products.
This servo amplifier is UL/C-UL-listed when using the fuses indicated in the following table. When the servo
amplifier must comply with the UL/C-UL Standard, be sure to use these fuses.
MR-J3-10A (1) 20A
MR-J3-40A 20A1
MR-J3-60A to
100A 40A1
MR-J3-350A
MR-J3-500A
(6) Attachment of a servo motor
For the flange size of the machine side where the servo motor is installed, refer to "CONFORMANCE WITH
UL/C-UL STANDARD" in the Servo Motor Instruction Manual.
(7) About wiring protection
For installation in United States, branch circuit protection must be provided, in accordance with the National
Electrical Code and any applicable local codes.
For installation in Canada, branch circuit protection must be provided, in accordance with the Canada
Electrical Code and any applicable provincial codes.
Fuse
Class
Current [A]
Voltage [V]
10
15
20
40
T
70
125
150
200
250
350
Servo amplifier
MR-J3-500A4
AC250
MR-J3-700A4
A - 12
Fuse
Class
Current [A]
Voltage [V]
10
15
25
35
T
50
65
100
150
175
AC600