Mitsubishi Electric Melservo MR-J3-A Instruction Manual page 4

Servo amplifier
Table of Contents

Advertisement

4. Additional instructions
The following instructions should also be fully noted. Incorrect handling may cause a fault, injury, electric
shock, etc.
(1) Transportation and installation
Transport the products correctly according to their weights.
Stacking in excess of the specified number of products is not allowed.
Do not carry the servo motor by the cables, shaft or encoder.
Do not hold the front cover to transport the servo amplifier. The servo amplifier may drop.
Install the servo amplifier in a load-bearing place in accordance with the Instruction Manual.
Do not climb or stand on servo equipment. Do not put heavy objects on equipment.
The servo amplifier and servo motor must be installed in the specified direction.
Leave specified clearances between the servo amplifier and control enclosure walls or other equipment.
Do not install or operate the servo amplifier and servo motor which has been damaged or has any parts
missing.
Provide adequate protection to prevent screws and other conductive matter, oil and other combustible
matter from entering the servo amplifier and servo motor.
Do not drop or strike servo amplifier or servo motor. Isolate from all impact loads.
When you keep or use it, please fulfill the following environmental conditions.
Environment
During
operation
Ambient
temperature
In storage
Ambient
In operation
humidity
In storage
Ambience
Altitude
(Note)
[m/s
Vibration
Note. Except the servo motor with reduction gear.
Securely attach the servo motor to the machine. If attach insecurely, the servo motor may come off during
operation.
The servo motor with reduction gear must be installed in the specified direction to prevent oil leakage.
Take safety measures, e.g. provide covers, to prevent accidental access to the rotating parts of the servo
motor during operation.
Never hit the servo motor or shaft, especially when coupling the servo motor to the machine. The encoder
may become faulty.
Do not subject the servo motor shaft to more than the permissible load. Otherwise, the shaft may break.
When the equipment has been stored for an extended period of time, consult Mitsubishi.
Servo amplifier
[
]
0 to 55 (non-freezing)
[
]
32 to 131 (non-freezing)
[
]
20 to 65 (non-freezing)
[
]
4 to 149 (non-freezing)
90%RH or less (non-condensing)
90%RH or less (non-condensing)
Indoors (no direct sunlight) Free from corrosive gas, flammable gas, oil mist, dust and dirt
Max. 1000m (3280 ft) above sea level
2
]
5.9 or less
CAUTION
Conditions
0 to 40 (non-freezing)
32 to 104 (non-freezing)
15 to 70 (non-freezing)
5 to 158 (non-freezing)
80%RH or less (non-condensing)
HC-UP 202 to 502
HA-LP701M to 15K1M
HA-LP502 to 22K2
HA-LP8014
HA-LP11K1M4
HA-LP11K24 to 22K24
HA-LP15K1 to 25K1 HA-LP22K1M
HA-LP15K14
A - 3
Servo motor
HF-MP Series
HF-KP Series
HF-SP 52 to 152
HF-SP 51
81
HC-RP Series
HC-UP 72
152
HF-SP 202
352
HF-SP 121
201
HF-SP 301
421
HF- SP 502
702
HA-LP601 to12K1
12K14
15K1M14
20K14 HA-LP22K1M4
X
Y : 49
X
Y : 24.5
X : 24.5
Y : 49
X : 24.5
Y : 29.5
X : 11.7
Y : 29.4
X
Y : 9.8

Hide quick links: