6. DISPLAY AND OPERATION SECTIONS
(2) Signed 6-digit or more parameter
The following example gives the operation procedure to change the electronic gear numerator (parameter
No. PA06) to "123456".
(Note)
Setting of upper 1 digits
Note. The example assumes that the status display screen that appears at power-on has been set to the servo motor speed
in parameter No. PC36.
Press MODE three times. Press UP or DOWN to choose parameter No. PA06.
Press SET once.
Press MODE once.
Press SET once.
The screen flickers.
Press UP or DOWN to
change the setting.
Press SET once.
Enter the setting.
Press MODE once.
6 - 12