SECTION 5—WHEELCHAIR OPERATION
FIGURE 5.8 MPJ Joystick Switches and Indicators - LCD Display
Emergency Stop/Reset Switch
The emergency stop/reset switch is used to stop the wheelchair and to select the operating
mode for the wheelchair. The switch input is located on the control module next to the
joystick input. An emergency stop/reset switch is needed whenever any of the following
operating modes are programmed:
• Environmental Controls (E.C.U.) - including recliner controls
• 3 Speed Mode in Momentary
• Latched Modes
• Pneumatic Control
• Stand-by Mode
• RIM Control
• Remote Drive Selection Mode
• Information Center Display Selection (does not require Reset activation at power up)
If any of the above modes are selected, the control will require activation of the switch
immediately after the power switch is turned on in order to enter the drive mode. The
second line of the LCD will display - PRESS RESET.
Emergency Stop/Reset Input
The input accepts a 1/8-inch diameter Phono connector. The emergency stop/reset switch
must be an open contact for normal driving and a closed contact to activate the emergency
stop/reset function.
PIN
TIP
RING
Remote On/Off Switch
The remote on/off switch input allows the power switch to be operated by an ability
switch (normally open momentary switch with mono plug). To use the remote on/off
feature, the Drive Select/On/Off switch must be in the ON position. Each activation of the
ability switch will alternately turn the joystick ON or OFF.
TDX™ Wheelchairs
DRIVE I
E
DESIGNATION
Emergency Stop/Reset
COMMON (B–)
66
MI
F
0000
Part No 1114809