Denso BHT-904B User Manual page 93

Barcode handy terminal
Table of Contents

Advertisement

"8: STF": Detail setting of the standard 2of5 (STF) reading
1.
Selec
t "2: STF" at the SET BARCODE menu and then press the ENT key.
Th
e SET STF screen appears.
"1
: MIN":
Sets the minimum number of the STF digits.
Setting range:
"2: MAX":
Sets the maximum number of the STF digits.
Setting range:
Always set the minimum number of digits to a number less than the maximum number o
 Point 
digits. If the minimum number exceeds the maximum number, a read error occurs.
"3: CD CHECK":
"ON":
Reading is carried out only if the check digit is correct. Reading is not carried out if either
the check digit is incorrect or does not exit.
"OFF":
Reading is carried out regardless of the presence of the check digit.
"4: TYPE :
"
"BOT
H":
"NORMAL":
"SHORT" :
2.
Use the cursor keys ([▲] [▼]) or numeric keys ([1] [2] [3] [4]) to
3.
Press the cursor keys ([◄] [►]) to select the desired setting.
4.
Press the ENT or Backspace/clear key to update the setting and return to the SET BARCODE
menu.
1 to 99
1 to 99
Enables readin
g of both normal and short types.
Enables reading of the normal type.
Enables reading of the short type.
Barcode Handy Terminal
select the desired item.
f
79