Denso BHT-904B User Manual page 194

Barcode handy terminal
Table of Contents

Advertisement

BHT-904B/BHT-914B
Error No.
The
BHT
specification is illegal.
The Transfer Utility "Communication port"
option specification is illegal.
The transmission speed at the BHT and PC
does not match.
51
52
The
communication
uncorrespondence is set to CU.
The protocol specified at the BHT and PC
does not match.
The PC communication port setting is illegal.
Hardware malfunction.
The protocol specified at the BHT and PC
53
does not match.
The protocol specified at the BHT and PC
does not match.
An attempt was made to download a file with
55
field width differing from that of the data file
already existing in the BHT.
Illegal characters have been used in the file
55
name.
71
The COM port number used has already
been used.
The COM port number used doesn't exist.
75
The
communication
uncorrespondence is set to CU.
Illegal field information specification option
91
when transmitting data file.
180
Cause Details
communication
interface
condition
of
condition
of
Specify IrDA (Optical) if connected to the PC via
the CU, and Connector if connected via the
interface connector. Refer to QBdirect (page 175,
Note 1) for details of the setting method
Specify the communication port to which the BHT is
connected for the "Communication port" option.
Ensure that the transmission speed at the BHT and
PC matches.
Please be aware that the default transmission
speed differs depending on the BHT used.
the
CU-921 corresponds only to the transmission rate
115200bps and 460800bps.
Please set it to these transmission rates.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
Enable "Use FIFO buffer. (16550 interchangeable
UART required.) (U)" setting for the communication
port used.
Please contact your dealer.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
Ensure that the protocol matches.
Please be aware that the default protocol differs
depending on the BHT used.
It is not possible to download a file with the same
name but different field width from the file already
existing in the BHT.
Either delete the existing data file in the BHT, or
specify the same field format as the existing data
file.
Change the file name.
Refer to QBdirect (page 175, Note 1) for details of
characters that can be used in file names.
Please use another COM port number, or use it
after shutting the COM port under use.
Please use the existing COM port number.
the
CU-921 corresponds only to the transmission rate
115200bps and 460800bps.
Please set it to these transmission rates.
Set a correct value for the field information option.
Remedy