 Important 
Receiving the BHT-BASIC data files (Method of specifying the field information)
The data files received via the MTP connection do not contain the field information; therefore those
data files can not be used in the BHT-BASIC applications.
Use the following procedure to receive a data file as a data file that contains the field information.
1. Create the "MTPFLD.INI" (MTP field information file) which is stated data file name and field
information.
2. Save the "MTPFLD.INI" in the BHT. (Downloading by MTP is possible.)
3. Download the data file by MTP. (Convert the data file to the data file containing the field
information according to the statement of the "MTPFLD.INI".)
(The data file is converted to the data file containing the field information according to the
statement of the "MTPFLD.INI".)
File format of the "MTPFLD.INI"
・The "MTPFLD.INI" is a data file with one filed (field length 256).
・State the field as "field name : field information".
MASTER.DAT:10,14,20,4,8,128
TENPO.TXT:8,8,8
URIAGE.DAT:64