How to Change Language Display

1. Enter program mode. (See Section 5.1.)
1
2. Press
for general options.
2
3. Press
for display options.
4. Press
until the display flashes on the language format field.
5. Press the
or
Note: Only English format is available at this time.
ENTER
6. Press
.
MENU
5–8
Table 5–4: Display Options and Descriptions (cont'd)
Choices
Default
No
No
No
No
No
English
Code
English
Code
0 .. 9
Packed
Zero
SIA
button until the display flashes on the desired setting.
See Section 5.4.2.5 for step-by-step instructions.
If "English" is selected then the printer and VFD output for calls of
these formats will be text descriptions. If "Code" is selected then
the printer and VFD output for calls of these formats will be the
Code and Zone numbers. See Section 5.4.2.6 for step-by-step
instructions.
If "English" is selected, the printer and VFD output will be text. If
"Code" is selected then the printer and VFD will display the SIA
codes followed by zone or other information. See Section 5.4.2.6
for step-by- step instructions.
This option only affects the ADEMCO 8000 automation protocol
output. If "English" is selected each event will be sent to the
automation as two SIA events; the first with the two digit Group
number and the second with the three digit ID number. If "Code" is
selected, each event is sent as eleven digits; two digits Message
type, one-digit Event Qualifier, three-digit Event Code, two-digit
Group Number, and three-digit ID number. See Section 5.4.2.6 for
step-by-step instructions.
If "0 .. 9" is selected hexadecimal digits B through F are forced to
0 as in the way the SK9000 receiver does it, or if "0 .. F" is
selected digits are sent as is.
Each data packet to the automation contains a single (unpacked)
or multiple (packed) events.
Defines leading character in a 3-digit account number as a zero or
space.
Printer output will be in SIA format if "SIA" is selected or in a raw
data high speed format if "Hispeed" is selected.
VFD will display the last acknowledged event instead of the
date/time display in the auto mode. In manual mode the display
will show the oldest unacknowledged event.
Set the brightness of the Normal Operating Mode Display screen.
All other screens will be displayed at Maximum.
See Section 5.4.2.8 for step-by-step instructions.