MX8000 Installation and Operation Guide
9. Enter the desired time (from 01-99 seconds).
ENTER
10. Press
.
MENU
11. Press
to exit menu.
4.6.9

Program Menu

If program is selected from the main menu the
system will enter into "Program Mode". (See Section
4.5 for information on modes of operation.) In
program mode you can program all the general
options, line card options, and user list. (See
Appendix A, Table A–1 for Programming Quick
Chart.)

4.6.10 Diagnostics Menu

The diagnostics menu items can be used while
testing and troubleshooting the system.
4.6.10.1 Phantom Menu
The phantom menu contains list of various communication format phantom signals (see Table 4–8) that can
be used to test the receiver or automation software configurations. For example, you set a line cards
parameters for a particular communications format and would now like to verify that this new configuration
will communicate with other communication formats, you can send phantom signals in the formats you wish
to test that line card with. To use the phantom menu to test a format:
1. Select Phantom Menu in the Diagnostics Menu.
2. Scroll through the list of formats and select the format to be tested.
3. Exit the Phantom Menu. Messages will be sent to the printer in the format selected.
Choice
01 DCS
02 CID
03 ITI
04 BFSK
05 3/1
06 3/2
07 4/1
08 4/2
09 FSK0
10 FSK1
11 FSK2
Note: This format is not currently supported by the MX8000.
4–16
Table 4–8: Phantom Signals Formats List
Format
DCS
Contact ID®
ITI format
BFSK
3/1 format
3/1 format w/checksum
4/1 format
4/2 format
FSK0
FSK1
FSK2
<Program Menu>
1=General Options
2 Line Device Menu
3 User List
Figure 4–17: Program Menu Items
<Diagnostics>
1 Phantom Menu
2 Message Que
3 Event Log
<Diagnostics>
4=Format-Raw Hex
5 LC Debug Mode
6 LC Statistics
<Diagnostics>
7=Port Status
< Exit Menu
Figure 4–18: Diagnostics Menu Items
Choice
12 SIA D1
13 ADM42 Cksum
14 SIA D1 Cksum
15 ACRON TOUCH TONE
16 ADM41 Cksum
17 FBII 4+3+1
18 Modem IIE
19 SIA 2000 (see note)
¯
¯
­
¯
­
Format
ADEMCO High Speed (SIA D1)
ADEMCO 4/2 format w/
checksum
ADEMCO High Speed w/
checksum (SIA D1 w/checksum)
Acron TouchTone
ADEMCO 4/1 format w/
checksum
FBII 4+3+1
Modem IIe format
SIA 2000 format