Honeywell ADEMCO MX8000 Installation And Operation Manual page 60

Digital alarm receiver
Hide thumbs Also See for ADEMCO MX8000:
Table of Contents

Advertisement

MX8000 Installation and Operation Guide
General Options
Level 1 Choices
Items
FMT
(Edit Format
options continued)
Display Options
(continued)
Hold Last Event
VFD Brightness
Port Functions
Communication
Com Port 1
Com Port 2
Par Port
Automation Config
5–4
Table 5–2: General Options Items and Description (cont'd)
Level 2 Choices
SK9000
ACRON
HISPEED
Yes
No (default)
Off
25% (default)
50%
75%
MAX
Com1
Com2
Par (Parallel)
Baud Rate
D (# Data Bits)
S (# Stop Bits)
P (Parity)
PortMon (Port
Monitor)
F (Flow Control)
Init String
Same as Com Port
1
Edit Init String
Format
Hex
Heart Beat
Time (of Heartbeat)
Ack timeout
Level 3 Choices
Packed (default)
Each data packet to the automation
computer contains multiple events.
Unpacked
Each data packet to the automation
computer contains a single event.
Zero (default)
Defines leading character in a 3-digit
account number as a zero or space.
Space
SIA (default)
Printer and automation outputs will be
in SIA format if "SIA" is selected.
Hispeed
Printer output will be in SIA format and
automation output in a raw data high
speed format if "Hispeed" is selected.
VFD will display the last or oldest
unacknowledged event instead of the
date/time display. See 5.4.2.7.
Affects main menu display only. All
other displays are always at
maximum.
See Section 5.4.2.8.
Unused/Automation/
Rules for Port Configuration:
Printer/
1. Functions in Brackets [ ] will not
appear unless "Automation" is
Unused/[Auto Bkp]/
selected for Com1 function.
[Auto Bkp Prn]/
2. Functions in { } will not appear
{Print Bkp}/Diag/
unless "Printer" is selected in
Printer
Com1 or Par.
Unused/[Auto Bkp]/
3. A function may be selected only
Printer/Diag
once in the 3 ports (only one
printer, only one Diag, and so on).
4. All ports may be configured
"Unused".
See Section 5.4.3 for additional
information.
38400/19200/9600/
See Section 5.4.3.2.
7200/4800/2400/
1200/ 600/300/110
7, 8
1, 2
Even, Odd, No
Yes
When set to Yes (recommended) the
computer ready line is monitored.
No
Hdwr, None
None = no supervision
Sfwr
See Section 5.4.3.4.
See Section 5.4.3.3.
See Section 5.4.3.4.
SK9000, ADEM
See 5.4.3.5.
8000, ADEM 685,
FBII 220, CAPS, ITI
Gen, ITIComp
Y = Enabled
Only visible if ADEM 8000 or SK9000
format is selected.
N = Disabled
Y = Enabled
N = Disabled
10-600 Seconds
1-120 Seconds
Comments