Pppoe Ia For Vlan - ZyXEL Communications GS1920-24 User Manual

Gs1920 series intelligent layer 2 gbe switch
Hide thumbs Also See for GS1920-24:
Table of Contents

Advertisement

Advanced Application > PPPoE > Intermediate Agent > Port > VLAN (continued)
Table 111
LABEL
Remote-id
Apply
Cancel
28.3.3
PPPoE IA for
Use this screen to set whether the PPPoE Intermediate Agent is enabled on a VLAN and whether the
Switch appends the Circuit ID and/or Remote ID to PPPoE discovery packets from a specific VLAN.
Click the VLAN link in the Intermediate Agent screen to display the screen as shown.
Figure 174
The following table describes the labels in this screen.
Advanced Application > PPPoE > Intermediate Agent > VLAN
Table 112
LABEL
Show VLAN
Start VID
End VID
Apply
VID
*
Enabled
Circuit-id
DESCRIPTION
Enter a string of up to 63 ASCII characters that the Switch adds into the Agent Remote ID
sub-option for this VLAN on the specified port. Spaces are allowed.
If you do not specify a string here or in the Remote-id field for a specific port, the Switch
automatically uses the PPPoE client's MAC address.
The Remote ID you configure here has the highest priority.
Click Apply to save your changes to the Switch's run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Click Cancel to begin configuring this screen afresh.
VLAN
Advanced Application > PPPoE > Intermediate Agent > VLAN
DESCRIPTION
Use this section to specify the VLANs you want to configure in the section below.
Enter the lowest VLAN ID you want to configure in the section below.
Enter the highest VLAN ID you want to configure in the section below.
Click Apply to display the specified range of VLANs in the section below.
This field displays the VLAN ID of each VLAN in the range specified above. If you configure
the * VLAN, the settings are applied to all VLANs.
Use this row to make the setting the same for all VLANs. Use this row first and then make
adjustments on a VLAN-by-VLAN basis.
Changes in this row are copied to all the VLANs as soon as you make them.
Select this option to turn on the PPPoE Intermediate Agent on a VLAN.
Select this option to make the Circuit ID settings for a specific VLAN take effect.
GS1920 Series User's Guide
Chapter 28 PPPoE
238

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs1920-24hpGs1920-48Gs1920-48hp

Table of Contents