The following table describes the labels in this screen.
Management > Diagnostic
Table 162
LABEL
DESCRIPTION
System Log
Click Display to display a log of events in the multi-line text box.
Click Clear to empty the text box and reset the syslog entry.
Ping Test
IPv4
Select this option if you want to ping an IPv4 address, and select which traffic flow (in-
band or out-of-band) the Switch is to send ping frames.
If you select in-band, the Switch sends the frames to all ports except the management
port (labelled MGMT).
If you select out-of-band, the Switch sends the frames to the management port
(labelled MGMT).
IPv6
Select this option if you want to ping an IPv6 address. You also need to select the IPv6
interface type and specify the ID number of interface through which the Switch is to
send ping frames.
IP Address
Type the IP address of a device that you want to ping in order to test a connection.
Click Ping to have the Switch ping the IP address (in the field to the left).
Ethernet Port Test
Enter a port number and click Port Test to perform an internal loopback test.
Cable Diagnostics
Enter a port number and click Diagnose to perform a physical wire-pair test of the
Ethernet connections on the specified port(s). The following fields display when you
diagnose a port.
Port
This is the number of the physical Ethernet port on the Switch.
Channel
An Ethernet cable usually has four pairs of wires. A 10BASE-T or 100BASE-TX port only
use and test two pairs, while a 1000BASE-T port requires all four pairs.
This displays the descriptive name of the wire-pair in the cable.
Pair status
Ok: The physical connection between the wire-pair is okay.
Open: There is no physical connection (an open circuit detected) between the wire-pair.
Short: There is an short circuit detected between the wire-pair.
Unknown: The Switch failed to run cable diagnostics on the cable connected this port.
Unsupported: The port is a fiber port or it is not active.
Cable length
This displays the total length of the Ethernet cable that is connected to the port when the
Pair status is Ok and the Switch chipset supports this feature.
This shows N/A if the Pair status is Open or Short. Check the Distance to fault.
This shows Unsupported if the Switch chipset does not support to show the cable
length.
Distance to
This displays the distance between the port and the location where the cable is open or
fault
shorted.
This shows N/A if the Pair status is Ok.
This shows Unsupported if the Switch chipset does not support to show the distance.
Locator LED
Enter a time interval (in minutes) and click Blink to show the actual location of the
Switch between several devices in a rack.
The default time interval is 30 minutes.
Click Stop to have the Switch terminate the blinking locator LED.
Chapter 39 Diagnostic
GS1920 Series User's Guide
327