Texas Instruments 990 User Manual page 91

Dx10 hdlc communications package
Hide thumbs Also See for 990:
Table of Contents

Advertisement

Applications Programming
02
Illegal I/O opcode in byte 2, that
is,
not
within the range of 2 through 7.
03
Invalid source identification (SID) in bytes
16 and 17.
04
When executing a read call,
no
has
been
received
for
the
process.
input
data
program
to
05
When executing a write call either:
*
no
buffer
system
to
or
is
available
in
the
accept the output data,
*
no buffer is currently available to
accept the request
for
activation
services.
06
The communications package is not active.
07
An applica tions prog ram a ttempted to execute
a
privileged operation by requesting an I/O
opcode greater than 7.
08
Invalid destination identification (DID)
in
byte s 14 and 15.
09
When executing a write call,
output
buffer
length
is too large.
When executing a read
call, input buffer length is too small.
OA
The DID specified is inoperative,
that
is,
the sta tion is not active.
OB
When executing a write call,
no
buffer
is
available
to accept the output data for the
sta tion.
Byte
2
contains
the
I/O
opcode
supplied
by
the
applications
program.
For
normal
read or write
operations, the
I/O
opcodes
are
2
and
3;
for
requests
from
activation
services,
I/O
opcodes
range from 4 through 7.
I/O opcodes greater than 7
are
privileged
codes
reserved
for
use
by
the
communications package software.
2270526-9701
4-5

Advertisement

Table of Contents