Symptoms
The engine starts but
stalls immediately
Black or white smoke exhaust
from the muffler successively
The engine wont stop
Welding Arc is weak
Welding Arc is too
strong
NO AC Output
Weak AC Output
Slow-down does not
activate
Remote Control does
not work
Presumable Causes
1. Insufficient Oil
2.
High Water Temperature,
Insufficient Coolant/Water
3. Unable to charge
1. Overload
1. Stop Solenoid Disorder
1. Output Selector Switch
o r
DUAL
at
E CO
『
』
『
2. Freq. Switch at 50Hz
』
3. Current Dial Position
4. Poor Contact on Cables
5. Improper Diameter or Length of Cable
6. Poor Contact to material
7. Simultaneous use
1. Output Selector Switch
R EGULAR
at
『
S INGLE
』
o r
『
2. Current Dial Position
1. Breaker at
ON
『
』
2.Selector Switch at
ECO
『
1. Wrong Frequency
2. The rated current of load exceeds the rated
output of the equipment
3. Simultaneous use
1. Welding Cable short-circuit
2
T he power consumption
.
Of the load is 0.5A or below
1. Connected to AC100/110V receptacle by mistake
2. Connected AC100V load to remote control
receptacle
3. The switch (breaker) on the cord reel at
38
1. Replenish Oil
2. Keep the rated
Replenish coolant/water
3. Repair
1. Keep the rated output
1. Turn the lever to
to stop and repair
1. Change to
or
』
2
Change to
.
3. Turn it clockwise more
4
Connect sufficiently
.
5. Change the cable as per
CABLES
6. Connect securely
7. Stop using AC Output
1
Change to
.
or
』
2. Turn it counterclockwise more
1
Change to
.
2. Change to
』
『
1. Change to the load frequency
2. Refer to
Stop welding
1. Repair the short-circuit
2. Chang the slow-down
switch to
1. Connect to the remote control
receptacle
2. Disconnect the AC100V plug
3
Change the switch to
『
O FF
』
.
Actions
C LOSE
『
』
SINGLE
『
』
REGULAR
『
』
60Hz
『
』
SELECTION – WELD
『
』
ECO
『
』
DUAL
『
』
ON
『
』
『
S INGLE
』
,
『
D UAL
R EGULAR
O UTPUT LIMITATION
『
OFF
『
』
ON
『
』
』
o
』