10. Simultaneous use of Generating and Welding
The circuit breakers react on the AC power supply circuit only. In the simultaneous use of welding and
generating, there may be happen overload to the engine. Refer to the following table and limit AC power use.
Limitation of AC Power Supply in the simultaneous use of welding and generating (60Hz)
DGW310DMC
Welding Output
Rod/Current
φ2.0mm/60A
φ2.6mm/120A
φ3.2mm/140A
φ4.0mm/170A
φ5.0mm/240A
φ6.0mm/300A
The 1-P figure shown is the total output of 1-P 100/110V and 200/220V.
DGW310MC
Welding Output
Rod/Current
φ2.0mm/60A
φ2.6mm/120A
φ3.2mm/140A
φ4.0mm/170A
φ5.0mm/240A
φ6.0mm/300A
The 1-P figure shown is the total output of 1-P 100/110V and 200/220V.
C aution
●Simultaneous use of Welding and AC Power is NOT available.
●Avoid simultaneous use in the case high welding quality is required.
Select
3-P Output (PF 0.8)
Dual
9.3kVA
Dual
7.2kVA
Dual
6.4kVA
Dual
5.2kVA
Single
2.0kVA
Single
0kVA
Select
3-P Output
Regular
9.3kVA
Regular
7.2kVA
Regular
6.4kVA
Regular
5.2kVA
Regular
2.0kVA
Regular
0kVA
AC Power Output
1-P Output
7.4kVA
5.7kVA
5.1kVA
4.1kVA
1.6kVA
0kVA
AC Power Output
1-P Output
7.4kVA
5.7kVA
5.1kVA
4.1kVA
1.6kVA
0kVA