6-2. Coolant and Water
Danger: Injuries
● Close all doors and locks during operating equipment to avoid injuries by accidental touch cooling fan or
fan belt.
Danger: Burns
● Do not open the radiator cap while operating the equipment or immediately after stopping the equipment to
avoid sustaining burn from hot vapor.
Caution: Burns
● Do not touch the engine or muffler during operation or immediately after stopping the equipment for
the temperature can reach extremely high.
Check to see if the coolant/water level is between
If it is below
L OW
l evel, fill he tank and the radiator accordingly.
(1) Filling the sub tank
1. Remove the sub tank cap.
2. Fill up the sub tank to
3. Install the cap again.
(2) Filling the radiator
1. Open the top plate.
2. Remove the radiator cap.
3. Fill the radiator up to the top/
4. Install the cap again and tighten.
5. Close the top plate.
C aution
● Use Long Life Coolant to prevent from freeze and rust.
(30% mixture LLC is filled when shipped out from factory)
F ULL
l evel.
F ULL
a nd
L OW
i n the sub tank.
Sub tank
17
Cap
Sub Tank
Top Door
Radiator
Cap
Water Inlet

Hide quick links: