9-2. Output Limitation
Please refer to the table below, because electric tools and home appliances cannot be judged only by the
rated.
The rated output or the power consumption due to the efficiency and character of components.
Loads
Electric Bulb, Heater, etc.
Electric Tools, etc. (Series
motor)
Mercury Lamp (high power
factor type)
Submersible Pump,
Compressor, etc. (induction
motor)
- 2 6 -
Series Motor
Induction Motor
The value described is
P OWER CONSUMPTION
『
C aution
<
<
<
<
>
>
>
>
● Be sure to use the frequency designated in the equipment incorporated in mercury
bulb or induction motor.
● The load incorporated in motor may require bigger power than the rated power
consumption.
So, consult with our authorized distributor or our engineering section to clarify.
● When connection to use 2 or more sets, start the load one by one, not to start them simultaneously.
● When starting a mercury bulb ON again, wait for about 15 minutes until it cools down.
Applicable Load (For reference only)
1-P 100/110V
Receptacle
Terminal
1pce
1 set
1.5
3.0
0.7
1.5
0.6
1.2
0.6
1.2
M otor with brush
:
B rushless Motor
:
O UTPUT
f or induction motor load and
『
』
for the other equipment.
』
Capacity(kW)
1-P 200/220V
Terminal
&
Terminal
receptacle
1 set
total
6.0
6.0
3.0
3.0
2.4
2.4
2.4
2.4
27
3-P 200/
220V
Total 3 terminal
Terminal
set
8.0
―
4.0
―
3.2
―
3.2
4.0