Final start-up procedure for GC124 SP models

13 Final start-up procedure for GC124 SP models
Lighting pilot
RISK TO LIFE
from fire or explosion.
Never use excessive force on the
WARNING!
ON/OFF knob (
Turn ON/OFF knob only by hand.
Never use tools to turn knob.
If you are unable to turn the knob by
hand, do not try to repair it.
Call Buderus technical service for
assistance.
1. Turn gas valve ON/OFF switch counterclockwise to
"PILOT" position (
2. Press and hold red pilot ignition button in
completely.
3. Ignite the pilot burner with the supplied match holder
and a burning match through the sight glass in the
burner housing.
4. After the pilot burner ignites, continue to hold the red
reset button for about a minute.
5. Release red pilot ignition button.
6. The red pilot ignition button must pop up and the
pilot burner must continue burning.
7. If the ignition burner goes out, turn ON/OFF switch
on gas valve clockwise to OFF and repeat steps 1
through 5.
RISK TO LIFE
due to poisoning by leaking gas.
If the red pilot ignition button does not pop
WARNING!
up when you release it, STOP and do the
following:
Close gas shut-off immediately to
prevent gas from leaking.
Contact your service technician or gas
supplier immediately and have the fault
repaired.
We reserve the right to make any changes due to technical modifications.
Installation and maintenance instructions Gas Boiler Logano GC124 II/SP • Issue 07/2006
Fig. 23).
Fig. 30).
2
Fig. 29 GC124 SP boiler
1 Sight glass
2 Thermocouple
3
2
1
Fig. 30 GC124 SP gas valve
1 Safety screw for igniter orifice pressure setting
2 ON/OFF knob (in ON position)
3 Red pilot ignition button
4 Screw plug for gas pressure measurement port
5 Safety screw for orifice pressure setting
6 Screw plug for orifice measurement port
13
1
4
5
6
35