Dimensions And Connections - Buderus Logano GC124 II/SP Installation And Service Instructions Manual

Gas boiler
Table of Contents

Advertisement

3

Dimensions and Connections

3
Dimensions and Connections
GAS ½"
EL ¾"
RK 1¼"
Fig. 2
Back, side and front view, measurements in inches
* optional connection
Connections (measurements see the following tables):
VK
= Boiler supply
RK
= Boiler return
EL
= Boiler drain
GAS = Gas connection
Boiler
Boiler
size
input
Btu/hr
18/3
74000
25/4
103000
32/5
132500
Tab. 1
Dimensions/specs for GC124 II and GC124 SP
USER NOTE
For the size and dimensions of the main
gas orifices, refer to
page 79.
8
2
VK 1¼"
A
B
Vent connection
Inches
Inches
13 1/8"
8"
16 3/4"
8 2/3"
20 3/8"
9 1/2"
Chapter 18,
Installation and maintenance instructions Gas Boiler Logano GC124 II/SP • Issue 07/2006
Min. relief valve
II/SP
capacity
Inches
lb/hr
5"
62
5"
86
6"
110
Fig. 3
Pressure drop/boiler
We reserve the right to make any changes due to technical modifications
(GAS ½")*
Number of
Water
Orifices
volume
Qty.
US Gal.
2
2.4
3
2.9
4
3.4
Dry
weight
lbs
228
287
349.5

Hide quick links: