Product Information

2
Product Information
These instructions provide the operator of the heating system with an
overview of the use and operation of the boiler.
The Logano G334X floor-standing gas boiler is generally referred to
below as a boiler.
2.1

Designated use

The boiler is designed for heating central heating system water and
indirect provision of domestic hot water (e.g. in a hot water storage
tank) in residential buildings or apartment buildings. Any other purpose
is considered improper use.
2.2

Product Description

The boiler is a gas floor standing boiler employing gas combustion.
The boiler is fully functional with the factory-installed
aquastat. A Logamatic 2107 controller can be installed
in addition to the factory-installed aquastat.
The boiler consists of the following main components ( Fig. 1):
• Automatic ignition unit and aquastat
• Logamatic 2107 control (optional control)
• Boiler casing and front cover
• Boiler block with insulation
• Burners
The burner controller, the aquastat and, if installed, the Logamatic 2107
controller monitor and control all electrical and operational components
of the boiler.
The boiler casing prevents energy loss and acts as soundproofing.
The boiler block transfers the heat generated by the burner to the boiler
water. The insulation reduces energy loss.
1
Fig. 1
Main boiler components G334X
[1]
Front wall of boiler
[2]
Boiler casing
[3]
Aquastat
[4]
Burner controller
[5]
Boiler block with insulation
[6]
Burners
4
3
3.1
Before commissioning, read the safety instructions in chapter 1.2 on
page 2 for your own safety.
Before operating the appliance
▶ Ask your heating contractor to provide detailed information about
how the boiler works and is operated.
2
3
4
5
6
6 720 810 547-01.1T

Start-up procedure

Operating tips

DANGER: Risk of fatal injury from failure to observe the
commissioning instructions and subsequent incorrect
operation!
Risk of fire and explosion from failure to observe the
startup instructions.
▶ Read the startup instructions carefully before
commissioning.
DANGER: Risk of fatal injury from gas explosion!
If you smell gas there is a danger of explosion.
▶ Close the gas shutoff valve.
▶ Open windows and doors
▶ Do not operate any electrical switches or telephones.
▶ Do not use any sockets.
▶ Extinguish all open flames. No smoking. Do not use
lighters.
▶ Warn all occupants of the building that they need to
leave the building.
▶ Do not ring doorbells.
▶ From outside the building: Notify the police and
fire department.
▶ From outside the building: Call the gas supply
company and a trained and certified installer or
service company.
NOTICE: System damage!
The following test must also be conducted at floor level,
because some gas types are heavier than air and may
accumulate at floor level.
▶ Check for odor of gas around the heating system.
DANGER: Risk of system damage and serious injury
from fire or explosion!
Any attempt to use force or to repair the gas shutoff
valve may cause a fire or explosion.
▶ Operate the ON/OFF knob on the gas valve by hand
only.
▶ Do not use any tools.
▶ If the ON/OFF knob on the gas valve cannot be
operated by hand: Do not repair it.
▶ Contact a qualified and certified service company.
NOTICE: Risk of system damage from corrosion.
▶ Do not use the appliance if any part of it has been
under water.
▶ Contact a qualified and certified service company.
Logano G334X – 6 720 811 239 (2014/05)