IQS 2 Skew

Documents
Test pattern: 82P524.
Specification
Refer to Table 1, Skew specifications.
Table 1 Skew specifications
Skew
Specification
Print Skew
Max: +/-2.5mm (7/64 inch) per 250mm (10 inches) (+/-1%)
Image Quality
IQS 2, IQS 3

IQS 3 Registration

Documents
Test pattern: 82P524
Specifications
Refer to Table 1.
Table 1 Registration measurement
Registration
Specification
Lead edge
4mm (5/32 inches) +/- 3mm (1/8 inches)
Top edge
4mm (5/32 inches) +/- 3mm (1/8 inches)