Cleaning and maintaining the Digital 9000 system
L 60 characteristics
Input voltage
Input current
Pin assignment of DC input
hollow jack socket
Charging voltage
Charging current
Charging principle
Compatible Sennheiser
accupacks
Charging time
Dimensions
Weight
Operating conditions
Ambient temperature
Relative humidity
Protection against dripping and
light splashing of liquids
Storage and transport conditions
Ambient temperature
Relative humidity
Protection against dripping and
light splashing of liquids
In compliance with
Europe
USA
Canada
12 to 15 V
max. 900 mA
max. 4.2 V
max. 2 x 1,000 mA
• CC CV method (Li-Ion charging method)
• Deep discharge recovery charge
• Capacity monitoring
• Accupack temperature monitoring
• Over/undercharge detection
• Charging time limit (approx. 8 hours)
• BA 60 (3.7 V, 1,600 mAh, Li-Ion)
• BA 61 (3.7 V, 2,030 mAh, Li-Ion)
with a completely discharged accupack and at room temperature
(approx. 20°C/68°F):
• 100% = approx. 180 min
• 70% = approx. 60 min
• automatic security switch-off after approx. 8 hours
approx. 80 x 87 x 62 mm (W x D x H)
approx. 160 g (without mains unit)
0°C to +35°C
with reduced charging power: 0°C to +45°C
25% to 95% (non-condensing)
the product must not be exposed to dripping and splashing (IP2X)
20°C to +70°C
5% to 95% (non-condensing)
the product must not be exposed to dripping and splashing (IP2X)
EMC:
EN 61000-6-2
EN 61000-6-3
Safety:
EN 60065
FCC 47 CFR Part 15 B
Industry Canada ICES 003