Disabling the Terminating Resistor {NEe 5146}:
The 8-pin dipswitch SWI pointed out
lfi
Figure Ie
determines if the terminating resistor is on or off. Whether
the terminating resistor is on or off depends on how it
IS
cabled to the controller. Refer to the following examples:
Example 1: 5146 is the only drive connected to daisy-chain cable
Switch positions 2 to 8 ON; position 1 should be OFF.
I
I
0
CONTROLLER
N
~~~~~~~~
t
12345678
Example 2: 5146 is connected to middle of daisy-chain cable
Switch positions 1 to 8 OFF on the drive connected to
middle connector of daisy-chain cable; switch positions 2 to
8 ON on the drive connected to the end connector of daisy­
chain cable.
I
I
I
0
~
CONTROLLER
~
N
t
~~~~~~~~
12345678
~~~~~~~~
12345678
SW1
DRIVE 1 ­
DRIVE 2­
(MIDDLE OF
TERMINATOR ON
DAISY CHAIN)
TERMINATOR OFF
18