3-6-7 Frequency Reference Selection

• This parameter selects the method for inputting frequency references for the Inverter.
• There are three methods for inputting frequency references. Select the method according to the
application.
Note 3G3JE Communications Models (RS-485) do not have external inputs to select the frequency,
so this parameter is not displayed.
P11
Frequency reference selection
Selected item Key/MSP/T.C
Description of Selections
Selected item
Key (key)
Frequency reference set using Digital Operator keys.
MSP (msp)
Frequency reference according to multi-step speed reference 0 (SS0) and multi-step speed
reference 1 (SS1).
T.C (t.c)
Frequency reference using temperature controller time-shared proportional pulses via multi-
step speed reference 0 (SS0).
3-6-8 Selecting the Function for the Multi-function Output
This parameter is used to select the function of the multi-function output.
P12
Multi-function output selection
Setting range 0 to 3
Description of Set Values
Set value
Function name
0 (0)
Not allocated
1 (1)
Zero speed
2 (2)
Frequency matching
3 (3)
Reverse operation
Description
---
Output turned ON when the output frequency is 0 Hz or opera-
tion is stopped.
Output turned ON when the output frequency and the frequency
reference are the same.
Output turned ON when the direction of rotation is set for
reverse operation.