Operation
3-1
Key Operation Flowchart
Press the Enter Key for at least 1 s.
Mode can be change during
operation or when stopped.
Adjustment Mode
SP1: Frequency reference1
Changed by Increment
and Decrement Keys.
SP2: Frequency reference 2
Changed by Increment
and Decrement Keys.
SP3: Frequency reference 3
Changed by Increment
and Decrement Keys.
SP4: Frequency reference 4
Changed by Increment
and Decrement Keys.
ACC: Acceleration time
Changed by Increment
and Decrement Keys.
DEC: Deceleration time
Changed by Increment
and Decrement Keys.
LOD: Application selection
Example: Changing the Set Value
Adjustment Mode
sp1
SP1
sp2
SP2
sp3
SP3
Power ON
All the indicators light when the power is turned ON.
(Key operations are disabled.)
RUN Mode
Press the Mode Key for at least 1 s.
Mode can be change only when stopped.
Mode cannot be change directly.
Frequency reference: Hz set
Changed by Mode Key.
Output frequency: Hz out
Changed by Mode Key.
Output current: A
Changed by Mode Key.
Accumulated operating time:
Kh
Changed by Mode Key.
Forward/reverse operation
selection: FWD/REV
Changed by Mode Key.
(1) Move to Adjustment Mode and
40.0
press the Enter Key to display
the present set value.
(2) Use the Increment and
Decrement Keys to change
the set value.
45 5
.
The data display will flash while
a set value is being changed.
(3) Press the Enter Key to enter
the desired setting.
50.0
Note: The data display will flash
while the setting is being
entered and will return to the
setting item name when the
flashing stops.
Press the Mode Key for at least 1 s.
Mode can be change
only when stopped.
Display/setting
P01: Rated motor current
P02: Accumulated operating
time standard
Display
P03: DC injection braking
frequency
Display
P04: Startup DC injection
braking time
Display
P05: DC injection braking-
to-stop time
P06: Maximum output
Display/setting
frequency
P07: Frequency reference
upper limit
P08: Frequency reference
lower limit
P09:
Momentary power
interruption restart selection
P10: Operation command
selection
P11: Frequency reference
(See
selection
note 1.)
P12: Multi-function output
selection
P13: Reverse rotation prohibit
selection
P14: Carrier frequency
selection
P15: Communications unit
number
P16: Communications
baud rate
(See
P17: Communications
note 2.)
data length
P18: Communications
stop bits
P19: Communications parity
P20: Parameter initialization
P21: Accumulated operating
time clear
P11 can be set only on Standard Models.
Note 1:
2:
P15 through P19 are displayed and can be
set only for Communications Models.
Chapter 3
Initial Settings Mode
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
Changed by
Increment and
Decrement Keys.
3-3