Key sequence
3-5-3 Selecting the Application (Setting V/f Patterns)
• Set the V/f pattern so that the motor output torque is adjusted to the required load torque.
• With the 3G3JE, either of the two patterns below can be selected as the pattern for V/f characteris-
tics.
• The 3G3JE has an automatic torque boost function. The suitable torque characteristics can be
obtained by simply selecting the load application.
LOD
Application selection
Selected item CNV/FAN
Selected item
Characteristics and
CNV (cnv)
Constant torque character-
istics (for conveyers)
FAN (fan)
Gradual decrease torque
characteristics (for fan)
Output voltage (V)
Indicator
Display example
None
dec
None
10.0
None
20.5
None
dec
application
Select for applications such as conveyers, where the load
torque is uniform regardless of the rotation speed and the
load moment of inertia is high.
Select for applications such as fans and pumps, where the
load torque is lower when the rotation speed is slower.
Constant torque
characteristics
Gradual decrease
torque characteristics
0
Explanation
Use the Increment and Decrement Keys to dis-
play dec on the data display.
When the Enter Key is pressed, the present set
value will be displayed.
Set the deceleration time using the Increment
and Decrement Keys. The data display will
flash.
Pressing the Enter Key will enter the set value.
When the data displays stops flashing, the
adjustment item name will again appear on the
data display.