Omron EasySpeed 3G3JE User Manual page 74

Compact simplified inverters
Table of Contents

Advertisement

Operation
(Hz)
100%
0%
Acceleration time
ACC
Acceleration time
Setting range 0.1 to 999 (s)
DEC
Deceleration time
Setting range 0.1 to 999 (s)
Setting the Acceleration Time
Key sequence
None
1 s min.
Setting the Deceleration Time
Key sequence
None
1 s min.
3-14
(Hz)
100%
0%
(t)
Setting unit 0.1 s
Setting unit 0.1 s
Indicator
Display example
@ Hz set
6.0
None
sp1
None
acc
None
10.0
None
20.5
None
acc
Indicator
Display example
@ Hz set
6.0
None
sp1
Maximum output frequency (P06)
(t)
Deceleration time
Changes during
operation
Default setting
Changes during
operation
Default setting
The entire display and simplified-LED indicators
will light (except for the COM indicator) when
the power supply is turned ON. The present fre-
quency reference will be displayed on the data
display.
Pressing the Enter Key for 1 s or longer
changes the mode to the adjustment mode.
sp1 will be displayed on the data display.
Use the Increment and Decrement Keys to dis-
play acc on the data display.
When the Enter Key is pressed, the present set
value will be displayed.
Set the acceleration time using the Increment
and Decrement Keys. The data display will
flash.
Pressing the Enter Key will enter the set value.
When the data displays stops flashing, the
adjustment item name will again appear on the
data display.
The entire display and simplified-LED indicators
will light (except for the COM indicator) when
the power supply is turned ON. The present fre-
quency reference will be displayed on the data
display.
Pressing the Enter Key for 1 s or longer
changes the mode to the adjustment mode.
sp1 will be displayed on the data display.
Chapter 3
No
10.0
No
10.0
Explanation
Explanation

Advertisement

Table of Contents
loading

Table of Contents