This completes the installation procedure for a single path configuration. Proceed to 4.3 Changing and
Checking the Setting of Detailed FC Card Information. To use the built-in HDD, shut down the system and
then add the HDD.
For a multipath configuration, proceed to step 4.2.7 For a multipath configuration.

4.2.7 For a multipath configuration

1.
Install the ETERNUS multipath driver.
Insert the CD-ROM disk of the ETERNUS multipath driver, and then run Setup.msi in the
Japanese\Server folder. Follow the instructions on the screen to perform the installation.
Remarks
At this time, leave the secondary FC path cable disconnected.
2.
Restore the multipath connection.
After the installation of the ETERNUS multipath driver, a message prompting you to restart the
system is displayed. Select [No], and manually shut down the operating system.
After once powering off the partition, connect the cable and then start the operating system. This
completes the work. To use the built-in HDD, confirm startup with a multipath before shutting
down the system, and then add the HDD.
Then, proceed to 4.3 Changing and Checking the Setting of Detailed FC Card Information.