Field
Loopback is not set
Unknown-speed mode
unknown-duplex mode
Link speed type is autonegotiation
link duplex type is autonegotiation
The Maximum Frame Length
Broadcast MAX-ratio
Unicast MAX-ratio
Multicast MAX-ratio
Allow jumbo frame to pass
PVID
Mdi type
Port link-type
Tagged VLAN ID
Untagged VLAN ID
Last clearing of counters: Never
Peak value of input
Peak value of output
Last 300 seconds input: 0
packets/sec 0 bytes/sec
Last 300 seconds output: 0
packets/sec 0 bytes/sec
Input (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0
multicasts, 0 pauses
Input (normal): 0 packets, - bytes
0 unicasts, 0 broadcasts, 0
multicasts, 0 pauses
input errors
runts
Description
The loopback testing function is disabled.
The port speed is unknown.
The duplex mode is unknown.
The interface will negotiate a speed with its peer.
The interface will negotiate a duplex mode with its peer.
Maximum Ethernet frame length allowed on the interface.
Broadcast suppression threshold as a percentage of the interface
transmission capability. When the threshold is exceeded, the interface
drops broadcast packets.
Unknown unicast suppression threshold as a percentage of the
interface transmission capability. When the threshold is exceeded, the
interface drops unknown unicast packets.
Multicast suppression threshold as a percentage of the interface
transmission capability. When the threshold is exceeded, the interface
drops multicast packets.
Maximum length of Ethernet frames that are allowed to pass through
the interface.
Port VLAN ID.
Cable type.
Link type of the interface, which could be access, trunk, or hybrid.
VLANs for which the interface sends packets without removing VLAN
tags.
VLANs for which the interface sends packets after removing VLAN
tags.
Time when the reset counters interface command was last used to clear
statistics on the interface. Never indicates that the reset counters
interface command was never used since the switch was started.
Peak value of inbound traffic, in Bps.
Peak value of outbound traffic, in Bps.
Average rate of input and output traffic in the last 300 seconds, in pps
and Bps.
Inbound traffic statistics (in packets and bytes) for the interface. All
inbound normal and abnormal packets (including unicast, broadcast,
and multicast), and pause frames were counted.
Inbound traffic statistics (in packets and bytes) for the interface. All
inbound normal packets (including unicast, broadcast, and multicast),
and pause frames were counted.
Inbound packets with errors.
Inbound frames shorter than 64 bytes, in correct format, and
containing valid CRCs.