Rrp12.4 Opt Assy Size (Pl12.1) - TallyGenicom 9045N Service Manual

Tallygenicom
Hide thumbs Also See for 9045N:
Table of Contents

Advertisement

RRP12.4 OPT ASSY SIZE (PL12.1)

Removal
1)
Release the HARNESS ASSY SIZE FDR1 (PL 12.1) from the hooks of the FRAME CVR L550
(PL 12.1).
2)
Remove the 2 screws (gold tapping, 8mm) securing the OPT ASSY SIZE to the FRAME CVR
L550.
3)
Shift the OPT ASSY SIZE in the direction of the arrow to release the bosses, and remove it
from the FRAME CVR L550.
4)
Disconnect the connector (P/J802) of the the HARNESS ASSY SIZE FDR1 from the connector
of the OPT ASSY SIZE.
BOSS
Replacement
1)
Shift the OPT ASSY SIZE in the opposite direction of the arrow, and install it to the FRAME
CVR L550 (PL 12.1) using the 2 screws (gold tapping, 8mm).
2)
Connect the connector (P/J802) of the HARNESS ASSY SIZE FDR1 (PL 12.1) to the connec-
tor of the OPT ASSY SIZE.
3)
Secure the HARNESS ASSY SIZE FDR1 to the FRAME CVR L550 using hooks.
Chapter 3 Removal and Replacement Procedures (RRPs)
1 - 217
HOOKS