RRP11.11 ROLL OCT LOWER (PL11.1)

Removal
1)
Remove the COVER REAR (PL 11.1). (RRP11.2)
2)
Remove the COVER OCT (PL 11.1). (RRP11.4)
3)
Remove the 2 screws (gold tapping, 8mm, gold 6mm) securing the SUPPORT OCT LEFT (PL
11.1).
4)
Remove the 2 screws (gold tapping, 8mm) securing the BRACKET MOTOR OCT (PL 11.1).
5)
Disconnect the harness conector of the MOTOR ASSY OCT , and remove the BRACKET
MOTOR OCT together with the MOTOR ASSY OCT (PL 11.1).
6)
Remove the GEAR 45 (PL 11.1), GEAR 19/37 (PL 11.1) and GEAR 19 (PL 11.1).
7)
Release the hook of the BEARING ROLL (PL 11.1) on the side of GEAR 19 , and remove it
from the HOUSING OCT (PL 11.1).
Be careful handling the hook of the BEARING ROLL. It is fragile and could break ifgiven
excessive force.
8)
Shift the ROLL OCT LOWER in the direction of the arrow to remove.
When removing, do not hold the rubber rollers of the ROLL OCT LOWER.