RRP4.4
GEAR NUDGER (PL 4.1)
Removal
1)
Open the COVER OPEN (PL 1.1).
2)
While pressing down the boss of the HOLDER LEFT (PL 4.1) at the back of the 150 FEEDER
ASSEMBLY, shift the HOLDER LEFT in the direction of the arrow to remove the 3 hooks (Figure
1).
3)
Remove the HOLDER LEFT from the SUPPORT NUDGER (PL 12.3). At the same time, the
ACTUATOR NO PAPER (PL 4.1) is removed.
4)
Release the hook of the ROLL ASSEMBLY NUDGER (PL 4.1), and pull the ROLL ASSEMBLY
NUDGER out from the SHAFT NUDGER (PL 4.1).
5)
Release the hook of the GEAR NUDGER, and pull the GEAR NUDGER out from the SHAFT
NUDGER.
When removing, do not touch the roller surface of the ROLL ASSEMBLY NUDGER and
GEAR NUDGER.
SUPPORT NUDGER
(PL5.1.4)
(PL 4.1.4)
HOLDER
LEFT
LIFT UP
(BOSS)
Chapter 3 Removal and Replacement Procedures (RRPs)
UNDER VIEW
A (SEE DETAILED VIEW)
ACTUATOR NO PAPER
(PL 4.1.6)
(PL5.1.6)
ACTUATOR NO PAPER
HOOK
Figure 1. Nudger Gear
1 - 61
GEAR NUDGER
(PL 4.1.10)
(PL5.1.10)
ROLL ASSY NUDGER
(PL 4.1.11)
(PL5.1.11)
HOLDER LEFT
(PL 4.1.5)
(PL5.1.5)
DETAILED VIEW OF A
HOOK
HOLDER
LEFT
JG3033AA