Rrp6.7 Harness Assembly Fuser (Pl 6.1) - TallyGenicom 9045N Service Manual

Tallygenicom
Hide thumbs Also See for 9045N:
Table of Contents

Advertisement

RRP6.7
HARNESS ASSEMBLY FUSER (PL 6.1)
Removal
1)
Remove the COVER REAR 500 (PL 7.1) (RRP7.9).
2)
Remove the COVER REAR (PL 1.1) (RRP1.1).
3)
Remove the FUSER ASSEMBLY (PL 6.1) (RRP6.8).
4)
Remove the COVER LEFT (PL 1.1) (RRP1.3).
5)
Remove the COVER RIGHT (PL 1.1) (RRP1.2).
6)
Remove the COVER EXIT 500 (PL 1.1) (RRP7.1).
7)
Remove the 500 EXIT ASSEMBLY (PL 7.1) (RRP7.2).
8)
Remove the COVER TOP (PL 1.1) (RRP1.4).
9)
Remove the COVER FRONT (PL 1.1) (RRP1.5).
10) Remove the BTR ASSEMBLY (PL 6.1) (RRP6.9).
11) Remove the DUCT FRONT (PL 6.1) (RRP6.2).
12) Remove the ROS ASSEMBLY (PL 6.1) (RRP6.1).
Be careful not to drop or strike the ROS Assembly with any tools or other objects.
13) Remove the SHIELD PLATE ROS (PL 6.1) (RRP6.3).
14) Remove the GUIDE TRAY LEFT (PL 5.1) (RRP5.8).
15) Remove the MOTOR COVER (PL 8.1) (RRP8.1).
16) Remove the SHIELD PLATE LVPS (PL 9.1) (RRP8.1).
17) Remove the GUIDE CRU LEFT (PL 6.1) (RRP6.4).
18) Release the hooks securing the COVER GUIDE CRU (PL 6.1) to the GUIDE CRU LEFT, and
remove the COVER GUIDE CRU together with the HARNESS ASSEMBLY FUSER (Figure 1).
Be careful handling the hooks of the GUIDE CRU LEFT. They are fragile and could break
if widen to much.
Chapter 3 Removal and Replacement Procedures (RRPs)
Figure 1. Fuser Harness Assembly
1 - 107

Advertisement

Table of Contents
loading

Table of Contents