2 Instructions
Sample program
0.00
0.01
0.02
0.03
0.04
0.05
Coding
Instruction
LD
LD
KEEP (011)
LD
AND NOT
LD
OR
KEEP (011)
Note KEEP(011) is input in different orders on in ladder and mnemonic form. In ladder form, input the set input,
KEEP(011), and then the reset input. In mnemonic form, input the set input, the reset input, and then
KEEP(011).
2-24
When CIO 0.00 goes ON in the left example, CIO 100.00
KEEP
is turned ON. CIO 100.00 remains ON until CIO 0.01
100.00
goes ON.
When CIO 0.02 goes ON and CIO 0.03 goes OFF in the
left example, CIO 100.01 is turned ON. CIO 100.01
remains ON until CIO 0.04 or CIO 0.05 goes ON.
KEEP
100.01
Operand
0.00
0.01
100.00
0.02
0.03
0.04
0.05
100.01