2 Instructions
FLOATING-POINT MULTIPLY (*F)
Multiplier
0
Numeral
+∞
–∞
NaN
Note 1 The results could be zero (including underflows), a numeral, +∞, or –∞.
ER
The Error Flag will be turned ON and the instruction will not be executed.
FLOATING-POINT DIVIDE (/F)
Divisor
0
Numeral
+∞
–∞
NaN
Note 1 The results will be zero for underflows.
2 The results could be zero (including underflows), a numeral, +∞, or –∞.
ER
The Error Flag will be turned ON and the instruction will not be executed.
2-240
0
Numeral
0
0
0
See note 1.
ER
+/–∞
ER
+/–∞
0
Numeral
ER
+/–∞
0
See note 2.
0
0 (See note 1)
0
0 (See note 1)
Multiplicand
+∞
–∞
ER
ER
+/–∞
+/–∞
+∞
–∞
+∞
–∞
Dividend
+∞
–∞
+∞
–∞
+/–∞
+/–∞
ER
ER
ER
ER
CP1E CPU Unit Instructions Reference Manual(W483)
NaN
ER
NaN
ER