Scl3 - Omron SYSMAC CP Series Instruction & Reference Manual

Cpu unit
Hide thumbs Also See for SYSMAC CP Series:
Table of Contents

Advertisement

2 Instructions

SCL3

Instruction
SCALING 3
Symbol
Applicable Program Areas
Area
Usage
Operands
Operand
S
Source word
P1
First parameter word
R
Result word
P1: First Parameter Word
15
P1
Offset of linear function
8000 to 7FFF (signed binary)
15
P1+1
∆X
0001 to 9999 (BCD)
15
P1+2
∆Y
8000 to 7FFF (signed binary)
15
P1+3
Maximum conversion
8000 to 7FFF (signed binary)
15
P1+4
Minimum conversion
2-284
Mnemonic
Variations
SCL3
@SCL3
Step program areas
OK
Description
0
0
0
0
0
8000 to 7FFF (signed binary)
Function
code
Converts signed BCD data into signed binary data
487
according to the specified linear function. An offset
can be input in defining the linear function.
SCL3
SCL3(487)
S: Source word
S
P1: First parameter word
P1
R
R: Result word
Subroutines
OK
Data type
WORD
WORD
INT
Note P1 to P1+4 must be in the same area.
CP1E CPU Unit Instructions Reference Manual(W483)
Function
Interrupt tasks
OK
Size
1
5
1