Transparency Print Quality Is Poor - Lexmark C77x Service Manual

C77/c78 series
Hide thumbs Also See for C77x:
Table of Contents

Advertisement

5061
Step
Actions and questions
3
ITU—Make sure that the ITU legs are properly seated
onto the rail at the right side of the printer. This is
visible by removing the yellow print cartridge.
Is the ITU seated correctly?

Transparency print quality is poor

Step
Actions and questions
1
Transparencies—Check the media type and
transparency in use.
Are the recommended transparencies and media type
used?
2
Is the quality of the transparency poor or do brown
colors appear when projected?
3
Fuser settings—From the Diagnostics menu select
fuser settings and set to high.
Does this fuser setting fix the problem?
4
Does the transparency have a splotchy appearance?
5
Transfer setting: High—From the Diagnostics menu set
Transfer setting to High.
Does this transfer setting fix the problem?
6
Transfer setting: Low—From the Diagnostics menu set
Transfer setting to Low.
Does this transfer setting fix the problem?
2-100
Service Manual
Yes
No
Alignment—
Reinstall the ITU.
Enter the
If the problem
Diagnostics
continues,
Menu. Perform
replace the ITU
the alignment for
assembly. See
the color
"ITU assembly
required. See
removal" on
"ALIGNMENT
page
MENU" on
page
3-11.
Yes
No
Go to step 2
Inform the
customer.
Go to step 3
Go to step 4
Problem resolved
Replace the fuser
assembly. See
"Fuser
assembly
removal" on
page
Go to step 5
Replace the
second transfer
roll. See
"Second
transfer roll
removal" on
page
Problem resolved
Go to step 6
Problem resolved
Replace the
second transfer
roll. See
"Second
transfer roll
removal" on
page
4-49.
4-44.
4-88.
4-88.

Advertisement

Table of Contents
loading

This manual is also suitable for:

C76xC780nC78xC770nC772nC782n

Table of Contents